Defining Waste
Auto Body Shops
Pollution Prevention Guide
|
 |
Defining
Haz Waste | Determining Generator Size | Haz
Waste Mgmt. | Solid Waste
A material is considered a waste by state and federal regulations when it can
no longer be used or reused and requires treatment or disposal. Before a waste
can be treated or disposed of, you have to determine if the waste is non-hazardous
or hazardous. This can be done by either applying your knowledge of what is
in the waste or analyzing the waste by an approved test method. There are specific
management and disposal rules and regulations that must be followed if the waste
is determined to be hazardous or non-hazardous.
Defining
A Hazardous Waste
Knowing what makes a waste hazardous is important for understanding why it
should be reduced or eliminated, and for selecting less-hazardous alternatives.
There are two types of regulated hazardous waste defined by the United States
Environmental Protection Agency (EPA): characteristic and listed.
Characteristic
A waste may be considered hazardous if it exhibits any one of the following
characteristics: ignitable, corrosive, reactive,
and toxic.
- Ignitable - An ignitable characteristic waste is a liquid
with a flash point (see Glossary for definition) below 140oF;
a non-liquid capable of causing fire through friction, absorption of moisture,
or spontaneous chemical changes; and/or a flammable compressed gas. Examples
include solvents and mineral spirits.
- Corrosive - A corrosive characteristic waste is an aqueous-based
liquid with a pH less than or equal to 2.0 (strong acid) or a pH greater than
or equal to 12.5 (strong base). Examples include battery acid and alkaline
cleaning solvents.
- Reactive - Reactive characteristic wastes are unstable
or undergo violent chemical reactions when combined with water or other materials.
Examples include hydrogen sulfide and bleaches.
- Toxic - A toxic characteristic waste is hazardous due to
the presence of metals or organic compounds. A test, called the Toxicity
Characteristic Leaching Procedure (TCLP), simulates leaching of the contaminant
through a landfill environment and into groundwater. There are 40 constituents
that EPA has established concentration limits for in the TCLP test. Examples
include wastes with high metal (lead, silver, etc.) content, such as hot tank
wastes.
Listed
A waste can also be considered hazardous if it appears on any one of four lists
of hazardous wastes contained in the federal Resource Conservation and Recovery
Act (RCRA) regulations. These wastes contain toxic constituents that have been
found to be harmful to human health and the environment. More than 400 chemicals
can be found on these lists.
- F-Listed Wastes - F-listed wastes are derived from a wide
variety of sources. Examples of F-listed wastes include specific halogenated
solvents used in degreasing (tetrachloroethylene and methylene chloride) and
non-halogenated solvents (xylene and acetone).
- K-Listed Wastes - K-listed wastes are derived from specific
manufacturing processes. Examples of K-listed wastes include wastewater
treatment sludge from the production of certain inorganic pigments.
- P-Listed (Acute*) and U-Listed Wastes - P- and U-listed
wastes are toxic discarded chemical products or off-specification products
and residues. Examples of P- and U-listed wastes include 2,4-Dinitrophenol
(2,4-D) and formaldehyde (The Small Business Handbook For Managing
Hazardous Wastes, 1996).
- *Acute (P-Listed) wastes are determined by EPA to be so dangerous
in small amounts that they are regulated more stringently.
Exempt Hazardous Wastes
There are wastes that meet the definition of a hazardous waste but may be exempt
from hazardous waste regulations. Instead, they are regulated under other state
or federal regulations (to be discussed later in this guide). They include:
- Hazardous wastes generated in the home (for example
oven cleaners and drain cleaners)
- Spent lead-acid batteries to be sent off-site for reclamation
(for example vehicle batteries)
- Scrap metal to be recycled
- Asbestos to be disposed of
- Polychlorinated biphenyls (PCBs) to be disposed of -
Regulated as a toxic substance by the EPA under the Toxic Substance Control
Act.
- Chlorofluorocarbons (CFCs) to be disposed of - Regulated
as a volatile organic compound by EPA under the Clean Air Act.
Universal Wastes
Based on United States Environmental Protection Agency standards (EPA), Universal
Waste Regulations encourage the recycling of specific hazardous
wastes. These wastes, if destined for recycling and not for disposal, are called
universal wastes (UW)*. Universal wastes include:
- Spent batteries other than lead-acid batteries
- Spent or canceled pesticides that have been recalled or
managed by a waste pesticide collection program
- Mercury-containing thermostats
- Spent electric tubes or bulbs that are hazardous due to
heavy metals concentrations
*Note that household hazardous wastes are excluded from universal waste
regulations.
The following is a brief description of universal waste management:
- Universal waste generator is any person, by site, whose
act or process produces hazardous waste or whose act first causes a hazardous
waste to become subject to regulation.
- Universal Waste Handler is a generator of universal waste
or the owner or operator of a facility that receives universal waste from
other universal waste handlers, accumulates universal waste, and sends universal
waste to another universal waste handler, to a destination facility, or to
a foreign facility.
- Small Quantity Handler of Universal Waste means a universal
waste handler who does accumulate less than a total of 5,000 kilograms (kgs)
of universal waste at any time.
- Large Quantity Handler of Universal Waste is a universal
waste handler who accumulates a total of 5,000 kgs or more of universal waste
at any time. This designation is retained through the end of the calendar
year in which the total of 5,000 kgs or more of universal waste is accumulated.
- Universal Waste Transporter transports universal waste
by air, rail, highway, or water.
- Universal Destination Facility treats, recycles, or disposes
of universal waste.
In general, universal waste generators:
- May not dispose of universal waste (by definition it must
be recycled).
- May not intentionally dilute or treat universal waste.
- Must manage universal waste so as to prevent releases to air, water, or
soil.
- Must immediately contain any releases of universal waste and clean up the
releases accordingly.
- Must inform employees regarding proper handling of universal waste and
emergency response procedures.
- May transport universal waste only to other universal waste handlers, destination
facilities, or a foreign destination
Determining
Your Generator Size
| If your shop creates regulated hazardous waste, you are considered a hazardous
waste generator. There are three types of hazardous waste
generators defined in federal and state hazardous waste regulations:
conditionally exempt, small, and large. Your generator status depends on
the amount of hazardous waste your shop produces each calendar
month. |
| Special Note:
Your generator size can change each month depending upon how much
hazardous waste you produce, so it's important to keep good records. |
|
Conditionally Exempt Generator
Conditionally exempt generators (CEGs) generate no more than 220 lbs (100 kgs)
or about 25 gallons of hazardous waste, or no more than 2.2 lbs (1 kg) of acute
hazardous waste in any calendar month. CEGs are required to meet much lighter
regulatory requirements than SGs and LGs.
Small Generator
Small generators (SGs) generate between 220 and 2,200 lbs (100 and 1,000 kgs)
of hazardous waste in any calendar month.
Large Generator
Large Generators (LGs) generate 2,200 lbs (1,000 kgs) or more
of hazardous waste, or more than 2.2 lbs (1 kg) of acute hazardous waste in
any calendar month (The Small Business Handbook For Managing Hazardous Wastes,
1996).
|
Hazardous
Waste Management
How you store, recycle, treat, and dispose of your hazardous waste
depends primarily on your generator size (discussed previously). The
following is a brief description of the management requirements for
hazardous waste generators.
|
| Special
Note: If you store used oil, you are required by most state
regulatory agencies to mark storage containers with the words USED
OIL. |
|
Conditionally Exempt Generators (CEGs)
CEGs are required to:
- Identify all hazardous wastes generated.
- Limit the amount of hazardous waste generated in any month to less than
220 lbs (100 kgs).
- CEGs do not have waste container labeling or accumulation time limit requirements
unless they accumulate more than 2,200 pounds of hazardous
waste. If they accumulate more than 2,200 pounds, all CEGs' hazardous waste
must be regulated as if generated and accumulated by a Small or Large Generator
(described below).
- Never generate more than 2.2 lbs (1 kg) of acute hazardous waste or 220
lbs (100 kgs) of soil contaminated from acute hazardous waste spills in any
calendar month.
Dispose of hazardous waste at one of the following facilities:
- A legitimate recycling facility
- A permitted Treatment, Storage, and Disposal (TSD) Facility
- A licensed Class II (municipal) solid waste management facility in accordance
with state solid waste management regulations, only if the waste is a solid
waste, and accepted by the facility owner/operator
Small Generators (SGs)
SGs are required to:
- Identify all hazardous waste generated.
- Obtain a U.S. Environmental Protection Agency (EPA) Identification Number
(defined in Glossary section).
- Mark containers of hazardous waste in accumulation areas (defined in Glossary
section) clearly with the words Hazardous Waste
and an accumulation start date. SGs may store their hazardous waste on-site
for up to 180 days (or up to 270 days if the waste must be transported further
than 200 miles to a designated facility) without a permit from the DEQ. Satellite
accumulation containers must be marked with the words Hazardous
Waste, or with other words that identify the containers' contents.
- Maintain a log book listing the type and amount of hazardous waste generated
per month, what has been removed, etc.
- Have emergency response measures in place.
- Store and label hazardous waste appropriately.
- Manifest all hazardous waste sent off-site.
- Dispose of hazardous waste only at a permitted TSD Facility.
Large Generators (LGs)
LGs are required to follow all the above requirements for SGs, in addition to
more stringent hazardous waste management requirements not covered in this guide.
For example, LGs can store their hazardous waste on-site for up to 90 days without
a permit. Satellite accumulation containers must be marked with the words Hazardous
Waste, or with other words that identify the contents of the containers.
Defining A Solid
Waste
A non-liquid waste that fails to meet the definition of a regulated hazardous
waste may be considered a solid waste. Solid waste can be defined as all putrescible
and non-putrescible wastes, including garbage, rubbish, ash, sludge from sewage
treatment plants, dead animals, appliances, construction and demolition debris,
and wood waste.There are two major types of solid waste landfills:
- Class II landfills - Designed to accept municipal solid
waste and non-hazardous industrial wastes.
- Class III landfills - Designed to accept inert materials
such as rock, soil, untreated wood waste, and tires.
Container sites, transfer stations, and composting facilities are also considered
solid waste management facilities.
Fact Sheet
3 of 18
Montana State
University Extension Service
Pollution Prevention Program Taylor Hall Bozeman, Montana 59717
|